What modelling program and ifc standard were used to create this model?
The model is created using Autodesk Revit Architecture 2011 - 1.0, and utilizes IFC2X3.
arc
4351
1
What is the space breakdown of the building grouped by floor with their respective areas and totals?
First Floor: - Kitchen: 33.2 mΒ² - Space 4: 279.7 mΒ² - Total First Floor Area: 312.9 mΒ² Second Floor: - Space 5: 197.4 mΒ² - Balkon: 116.1 mΒ² - Total Second Floor Area: 313.5 mΒ² Third Floor: - Women's Room: 4.6 mΒ² - Men's Room: 3.7 mΒ² - Space 8: 179.8 mΒ² - Total Third Floor Area: 188.1 mΒ² Roof: 201.7 mΒ²
arc
4351
3
What is the space breakdown of the first floor with respective areas and total?
First Floor Space Breakdown: - Kitchen: 33.2 sq m - Space 4: 279.7 sq m Total First Floor Area: 312.9 sq m
arc
4351
3
What is the space breakdown of the second floor with respective areas and total?
Space 5: 197.4 sq m Balkon: 116.1 sq m Total Second Floor Area: 313.5 sq m
arc
4351
3
What is the space breakdown of the third floor with respective areas and total?
Women's Room: 4.6 sq m Men's Room: 3.7 sq m Space 8: 179.8 sq m Total Third Floor Area: 188.1 sq m
arc
4351
2
What is the total gross floor area of the building?
Based on the gross area data available in the model, the total gross floor area of the building is 814.5 m¬².
arc
4351
3
What are the floor-to-floor heights between all consecutive levels?
The floor-to-floor height between levels is: - 01 First Floor to 02 Second Floor: 4.72 m - 02 Second Floor to 03 Third Floor: 4.42 m - 03 Third Floor to 04 Roof: 3.96 m - 04 Roof to 05 TO Parapet: 0.91 m
arc
4351
3
What door types are used in this building and their counts?
Door Types Used: - Single-Flush: 36" x 84": 10 doors (59%) - Single-Flush: 36" x 80": 4 doors (24%) - Door_Elevator_2-Speed_Reed: 2 doors (12%) - Double-Panel 1: 68" x 80": 1 door (6%) Total Doors: 17
arc
4351
2
What window types are used in this building and their respective counts?
Window Types Used: - Fixed: 36" x 72": 2 windows (67%) - Archtop with Trim: 108" x 108": 1 window (33%) Total Windows: 3
arc
4351
2
Which type of glazing is used in the windows?
Information not available in the BIM model.
arc
4351
4
What is the total cost of doors used in this building and the breakdown by door type?
Door Cost Breakdown: - Single-Flush: 36" x 84": $400 each Γ— 10 = $4,000 - Double-Panel 1: 68" x 80": $204 each Γ— 1 = $204 - Single-Flush: 36" x 80": $102 each Γ— 4 = $408 - Door_Elevator_2-Speed_Reed: $500 each Γ— 2 = $1,000 TOTAL DOOR COST: $5,612
arc
4351
2
What is the total cost of windows used in this building?
Costs Available in Model: - Archtop with Trim: 108" x 108": $900 each Γ— 1 = $900 Estimated Costs: (not available in model) - Fixed: 36" x 72": $350 each Γ— 2 = $700 TOTAL WINDOW ESTIMATED COST: $1,600
arc
4351
4
What is the percentage of wall volume that is load-bearing, including the volume breakdown?
Percentage of load-bearing walls by volume: - Load-bearing walls: 31.5 cu m (5.1% of total wall volume) - Total wall volume: 623.3 cu m
arc
4351
3
Could you provide a categorized breakdown of all walls in the building, including quantities of each wall type and their complete material compositions?
EXTERIOR WALLS: β€’ Basic Wall:Exterior - Brick on CMU (8 walls) Material Composition: 1. Masonry - Brick (0.09 m) 2. Misc. Air Layers - Air Space (0.08 m) 3. Insulation / Thermal Barriers - Rigid insulation (0.08 m) 4. Masonry - Concrete Masonry Units (0.19 m) 5. Metal - Furring (0.04 m) 6. Gypsum Wall Boa...
arc
4351
2
What types of walls are used in the exterior of the building, how many of each type are there, and what are their material compositions?
EXTERIOR WALLS: β€’ Basic Wall:Exterior - Brick on CMU (8 walls) Material Composition: 1. Masonry - Brick (0.09 m) 2. Misc. Air Layers - Air Space (0.08 m) 3. Insulation / Thermal Barriers - Rigid insulation (0.08 m) 4. Masonry - Concrete Masonry Units (0.19 m) 5. Metal - Furring (0.04 m) 6. Gy...
arc
4351
2
What walls are used in the interior of the building and what are they made of?
INTERIOR WALLS: β€’ Basic Wall:Interior - 3 1/8" Partition (1-hr) (10 walls) Material Composition: 1. Gypsum Wall Board (0.01 m) 2. Gypsum Wall Board (0.01 m) 3. Metal - Stud Layer (0.04 m) 4. Gypsum Wall Board (0.01 m) 5. Gypsum Wall Board (0.01 m)
arc
4351
2
What is the total volume of insulation material needed for exterior walls that have insulation material in their structure?
The total volume of insulation material needed is 82.20 cu m for exterior walls that have insulation material in their structure.
arc
4351
3
What is the thickness of each wall type?
The thickness of each wall type is: - Basic Wall:Exterior - Brick on CMU: 0.49 m - Basic Wall:Foundation - 12" Concrete: 0.30 m - Basic Wall:Generic - 12": 0.30 m - Basic Wall:Generic - 6": 0.15 m - Basic Wall:Interior - 3 1/8" Partition (1-hr): 0.08 m
arc
4351
2
What is the total length of interior walls?
The total length of interior walls is 17.18 m.
arc
4351
2
What is the total length of exterior walls?
The total length of exterior walls is 267.45 m.
arc
4351
3
Which door types have fire rating information?
No door types found with fire rating information.
arc
4351
2
Which door types have fire rating information?
No door types found with fire rating information.
arc
4351
2
What is the average door width in the building?
The average door width in the building is 0.99 m.
arc
4351
2
What is the largest door width that is used in the building?
The largest door width that is used in the building is 1.73 m.
arc
4351
2
What is the total interior wall surface area to be painted?
Total interior area for painting is approximately 1565.0 sq m.
arc
4351
3
Could you provide a breakdown of potential fire exits by room/space on each floor?
Information is not explicitely available in the BIM model, however potential fire exits are: First Floor: - Kitchen: 2 doors - Space 4: 3 doors Second Floor: - Space 5: 2 doors
arc
4351
4
Which rooms have direct access to outdoor spaces?
These rooms have access to the outdoors spaces through doors: First Floor: - Kitchen - Space 4 Second Floor: - Space 5
arc
4351
3
What are the specifications for the stairs used in the building?
Stair specifications: - Maximum riser height: 7 inches - Tread depth: 11 inches
arc
4351
1
What is the volume breakdown of floor slabs grouped by floor and the total volume?
FIRST FLOOR: 1. Floor:Generic - 12" Volume: 109.60 cu m Thickness: 0.305 m Level Total: 109.60 cu m (1 slab) SECOND FLOOR: 1. Floor:Generic - 12" Volume: 50.05 cu m Thickness: 0.305 m 2. Floor:Generic - 12" Volume: 54.46 cu m Thickness: 0.305 m Level Total: 104.51 cu m (2 slabs) ...
arc
4351
2
What is the total volume of concrete used?
The concrete volume is 668.07 cu m.
arc
4351
2
What is the total volume of concrete used in walls?
The concrete volume is 240.40 cu m.
arc
4351
3
What is the total volume of concrete used in floor slabs?
The concrete volume is 273.91 cu m.
arc
4351
3
What is the total volume of concrete used in foundation?
The concrete volume is 153.75 cu m.
arc
4351
3
What is the total surface area of the facade?
The total surface area of the facade is approximately 880 sq m.
arc
4351
3
Could you provide a breakdown of all furniture types in this building with the quantity of each type?
Furniture inventory by type: - Rectangular Table 68" x 30": 1 item - Rectangular Table 72" x 30": 3 items - Work Station Cubicle 96" x 96": 4 items - 35" Wide Base Cabinet: 2 items - Reed Laboratory Table: 3 items
arc
4351
2
What type of roof structure is used?
Information not available in the BIM model. However, a probable answer is that the roof is a flat reinforced concrete slab.
arc
4351
4
What is the structural concept of the building?
Information is not explicitly available in the BIM model, However, the structure is probably based on load-bearing wall system.
arc
4351
4
What electrical components are in this building and their counts?
The list of all electrical components present in the building are: 1. Duplex Receptacle - Standard (113 items) 2. Recessed Lighting Fixture - 2'x2'(2 Lamp) - 120V (101 items) 3. Duplex Receptacle - GFCI (12 items) 4. Lighting Switch - Three Way (8 items) 5. Lighting Switch - Single Pole (4 items) 6. Lighting Switch - F...
arc
4351
2
How many light switches are there?
There are 15 light switches overall.
arc
4351
2
What are the specific MEP system names and their corresponding types present in the building?
The MEP systems present in the building are: System Names: - Default Return Air (micky) - Default Supply Air (Pyro) - Default Supply Air (Queen) - Default Supply Air (micky) System Types: - Return Air - Supply Air
arc
4351
3
Which spaces have supply air and return air systems?
Information not available in the BIM model.
arc
4351
4
What is the total length of water supply piping in the building?
Information not available in the BIM model.
arc
4351
4
What plumbing fixtures are in this building and their respective counts?
The list of all plumbing fixtures present in the building are: 1. Toilet-Domestic-3D (9 items) 2. Sink Vanity-Round: 19" x 19" (6 items) 3. Urinal-Wall-3D (4 items) 4. Sink Kitchen-Double: 42" x 21" (2 items)
arc
4351
2
What phasing information is available?
Information not available in the BIM model.
arc
4351
4
What is the building's type and its function?
Building Type: Office Building Building Name: Buerogebaeude Total Levels: 5 floors
arc
ac20
1
What software and ifc standards were used to create this model?
IFC file generated by GRAPHISOFT ARCHICAD-64 20.0.0 GER FULL Windows version. IFC version is 4.
arc
ac20
1
What are the number of levels, building footprint area, total floor area, and total number of rooms/spaces?
Building Scale: - Number of Levels: 5 - Building Footprint Area: 537 sq m - Total Floor Area: 2266.7 sq m - Total Rooms/Spaces: 82
arc
ac20
2
What is the space distribution by level with areas and primary space functions with percentages?
Building Spatial Layout Overview: Total Building Levels: 5 storeys Total Spaces: 82 spaces across all levels Total Net Floor Area: 1939.4 sq m Space Distribution by Level: - Keller: 17 spaces, 438.1 sq m - Erdgeschoss: 18 spaces, 442.1 sq m - 1. Obergeschoss: 22 spaces, 428.4 sq m - 2. Obergesc...
arc
ac20
2
What is the space breakdown of the basement floor grouped by function with areas?
Basement Level (Keller): 17 spaces Total Area: 438.1 sq m Basement Level Spaces by Function: Besprechungsraum: - 001: 23.9 sq m - 002: 24.8 sq m Flur Keller Ost: - 017: 11.4 sq m Flur Keller Treppe: - 016: 45.6 sq m Flur Keller West: - 015: 34.3 sq m Labor: - 010...
arc
ac20
2
What is the space breakdown of the ground level grouped by function with areas?
Ground Level (Erdgeschoss): 18 spaces Total Area: 442.1 sq m Ground Level Spaces by Function: Buero Hausmeister: - 104: 12.4 sq m Buero Maier: - 111: 12.0 sq m Buero Mayer: - 109: 12.0 sq m - 110: 12.0 sq m Buero Mayr: - 107: 11.1 sq m Buero Meier: - 101: 11.1 sq...
arc
ac20
2
What is the space breakdown of the first floor grouped by function with areas?
First Level (1. Obergeschoss): 22 spaces Total Area: 428.4 sq m First Level Spaces by Function: Buero IL: - 207: 36.7 sq m Buero IL Sekr.: - 206: 24.8 sq m Buero Mueller: - 219: 11.1 sq m - 217: 12.0 sq m - 203: 24.8 sq m - 202: 24.8 sq m - 215: 12.0 sq m - 216...
arc
ac20
2
What is the space breakdown of the second level grouped by function with areas?
Second Level (2. Obergeschoss): 22 spaces Total Area: 428.4 sq m Second Level Spaces by Function: Buero (17 spaces): - 301: 23.9 sq m - 302: 24.8 sq m - 303: 24.8 sq m - 304: 24.8 sq m - 305: 24.8 sq m - 306: 24.8 sq m - 307: 23.9 sq m - 308: 11.1 sq m - 309: 12.0...
arc
ac20
2
What is the space breakdown of the attic floor with areas?
Attic Level (Dachgeschoss): 3 spaces Total Area: 202.4 sq m Attic Level Spaces: - 401: Flur 3.OG Treppe (60.2 sq m) - 402: Dachboden-1 (71.1 sq m) - 403: Dachboden-2 (71.1 sq m)
arc
ac20
2
What are the heights of each level?
Building Level Information: - Keller: Elevation: -3.0 m Height: 3.0 m - Erdgeschoss: Elevation: 0 Height: 3.0 m - 1. Obergeschoss: Elevation: 3.0 m Height: 3.0 m - 2. Obergeschoss: Elevation: 6.0 m Height: 3.0 m - Dachgeschoss: Elevation: 9.0 m Height...
arc
ac20
1
Which room in the building is the largest?
Largest Room: 006 Function: Seminarraum Area: 128.3 sq m Level: Keller Height: 2.70 m
arc
ac20
2
Which door types are installed in this building with quantities?
Total Doors: 77 Door Types and Quantities: - IFC TΓΌr - Eine Γ–Γ±ffnunsgrichtung: 67 doors (87.0%) - IFC DoppeltΓΌr - Eine Γ–Γ±ffnungsrichtung: 6 doors (7.8%) - IFC DoppeltΓΌr - Zwei Γ–Γ±ffnungsrichtungen: 3 doors (3.9%) - IFC TΓΌr - DrehtΓΌr: 1 doors (1.3%)
arc
ac20
2
Which two doors have the greatest widths in the building?
The two doors with the greatest widths in the building are: 1. "TΓΌr-019" - Width: 2.0 m 2. "TΓΌr-018" - Width: 1.8 m
arc
ac20
2
What is the narrowest door width used here?
Smallest Door Width: 1.0 m - IFC TΓΌr - Eine Γ–Γ±ffnunsgrichtung
arc
ac20
2
Which window types are present in the building and how many of each?
Total Windows: 206 Window Types and Quantities: - IFC Fenster - ein Panel: 206 windows (100.0%)
arc
ac20
2
What is the widest window in the building?
Largest Window Width: 1.0 m - IFC Fenster - ein Panel
arc
ac20
2
What is the narrowest window width used in this building?
Smallest Window Width: 0.9 m - IFC Fenster - ein Panel
arc
ac20
2
What wall types are present in the building and how many of each?
Total Walls: 121 Wall Types and Quantities: - Kalksandstein 2816491304 300: 59 walls (48.8%) - Kalksandstein 2816491304 200: 54 walls (44.6%) - Kalksandstein 2774059904 300: 8 walls (6.6%)
arc
ac20
2
Which wall types are used on the exterior side of the building and how many of each?
Total Exterior Walls: 54 Exterior Wall Types: - Kalksandstein 2816491304 300: 46 walls (85.2%) - Kalksandstein 2774059904 300: 8 walls (14.8%)
arc
ac20
2
Could you provide me with a list of all the different types of interior wall in the building and how many of each type there are?
Total Interior Walls: 67 Interior Wall Types: - Kalksandstein 2816491304 200: 54 walls (80.6%) - Kalksandstein 2816491304 300: 13 walls (19.4%)
arc
ac20
2
Which materials are used to construct the walls and their usage across wall types?
Total Wall Materials Identified: 1 Wall Materials and Usage: - Kalksandstein: 121 walls (100.0%) Kalksandstein 2774059904 300: 8 walls Kalksandstein 2816491304 200: 54 walls Kalksandstein 2816491304 300: 59 walls
arc
ac20
2
What materials are applied in the outer walls and their distribution across wall types?
Exterior Wall Materials: - Kalksandstein: 54 walls (100.0%) Kalksandstein 2816491304 300: 46 walls Kalksandstein 2774059904 300: 8 walls
arc
ac20
2
What materials are found in the internal walls and their distribution across wall types?
Interior Wall Materials: - Kalksandstein: 67 walls (100.0%) Kalksandstein 2816491304 300: 13 walls Kalksandstein 2816491304 200: 54 walls
arc
ac20
2
What are the thicknesses of the various wall types?
Wall Thicknesses by Type: - 200mm: 54 walls (44.6%) - 300mm: 67 walls (55.4%) Wall Type Breakdown: - Kalksandstein 2816491304 300: 300mm (59 walls) - Kalksandstein 2816491304 200: 200mm (54 walls) - Kalksandstein 2774059904 300: 300mm (8 walls)
arc
ac20
2
How many of the walls are load-bearing compared with non-load-bearing?
Load-bearing classification data is not available in this model.
arc
ac20
4
What is the total combined length of inside walls?
Total Interior wall length is 522.2 m.
arc
ac20
2
What is the total length of outside walls?
Total Exterior wall length is 643.8 m.
arc
ac20
2
What is the building's total net usable floor area with the breakdown by level?
Total Net Floor Area: 1939.4 sq m Net Floor Area by Level: - Keller: 438.1 sq m (22.6%) - Erdgeschoss: 442.1 sq m (22.8%) - 1. Obergeschoss: 428.4 sq m (22.1%) - 2. Obergeschoss: 428.4 sq m (22.1%) - Dachgeschoss: 202.4 sq m (10.4%) Area Comparison: - Gross Floor Area (from building levels): 2...
arc
ac20
2
Which coverings are applied throughout the building?
Total Coverings: 0 No Covering elements found in the model.
arc
ac20
4
Which ceiling materials are used in the building?
Ceiling Elements Found: 21 - Roof slabs (potential ceilings): 21 - Ceiling coverings: 0 Ceiling Materials: - Aluminium 131198
arc
ac20
1
What furniture items are present inside the building including quantities for each type?
Total Furniture Elements: 253 Furniture Types (Including generic names): - Objekt-006: 81 items - Objekt-002: 65 items - Stuhl: 55 items - Schreibtisch: 50 items - Unknown Furniture: 2 items Furniture Types: - Labortisch: 2 items - Schreibtisch: 50 items - Stuhl: 55 items
arc
ac20
2
Which sanitary fixtures are available in this building?
No Sanitary fixtures were found in this model.
arc
ac20
4
How many toilets exist on the ground floor?
Toilet/WC spaces on ground floor (Erdgeschoss): 2 Ground floor toilet spaces: - 113: WC Damen (12.4 sq m) - 112: WC Herren (12.4 sq m)
arc
ac20
2
Which stair types are used here with quantities?
Total Stairs: 4 Stair Types and Quantities: - Treppe-KG: 1 stair(s) - Treppe-EG: 1 stair(s) - Treppe-1-OG: 1 stair(s) - Treppe-2-OG: 1 stair(s) Related Circulation Elements: - Railings: 12 - Ramps: 0
arc
ac20
2
What is the total volume of the slabs with the breakdown by slab type?
Floor Slabs Analysis: - Total floor slabs: 5 - Total floor slab volume: 769.98 cu m Floor Slab Breakdown: - Decke-002: Volume: 154.80 cu m Area: 516.0 sq m Calculated Thickness: 300 mm - Decke-001: Volume: 156.42 cu m Area: 521.4 sq m Calculated Thickness: 300 mm - Decke...
arc
ac20
2
Which railing types are installed in the building?
Total Railings: 12 Railing Types: - Gelaender-1-1: 1 railing(s) - Gelaender-1-2: 1 railing(s) - Gelaender-1-3: 1 railing(s) - Gelaender-2-1: 1 railing(s) - Gelaender-2-2: 1 railing(s) - Gelaender-2-3: 1 railing(s) - Gelaender-3-1: 1 railing(s) - Gelaender-3-3: 1 railing(s) - Gelaender-3-2...
arc
ac20
2
Which rooms have the tallest ceilings?
All rooms have a ceiling height of 2.70 m.
arc
ac20
2
Which types of doors include fire rating details?
No door types have fire rating information in this model.
arc
ac20
4
Which windows have fire rating information?
No window types have fire rating information in this model.
arc
ac20
4
Which structural components exist in this building?
Structural Elements Summary: - Beams: 0 elements - Columns: 2 elements - Floor slabs: 5 elements - Roof slabs: 21 elements - Foundations: 0 elements - Structural members: 0 elements - Structural connections: 0 elements Total Structural Elements: 28
arc
ac20
1
Which beams are used in the building?
No beam elements found in the model. This may indicate a flat slab construction system or wall-bearing structure.
arc
ac20
4
Which column types are present here and how many of each?
Total Columns: 2 Column Types and Quantities: - Stahlbeton 2747937872 D200: 2 columns (100.0%) Column Materials (from type names): - Steel: 2 columns
arc
ac20
2
What are the sizes of the columns?
Column Dimensions by Type: - Stahlbeton 2747937872 D200: Γ–Γ²200mm (circular column) (2 columns) Column Shape Distribution: - Circular columns: 2
arc
ac20
1
Which slab types are present with quantities and thicknesses?
Slab Type Overview: - Floor slabs: 5 - Roof slabs: 21 - Total slabs: 26 FLOOR Slabs: - Decke-002: 3 slab(s) Thickness: 300 mm - Decke-001: 2 slab(s) Thickness: 300 mm ROOF Slabs: - Dach-001: 21 slab(s) Thickness range: 375 - 394 mm Average thickness: 380 mm Total area...
arc
ac20
2
Which roof structure elements are used?
The roof is represented by 21 aluminium slabs that form the curved surface. In practice, these slabs would usually act as cladding elements rather than primary structural components. A complete structural roof system of this type would normally require supporting elements such as trusses, beams, etc to transfer loads t...
arc
ac20
3
Which MEP systems are installed in this building?
No explicit MEP systems found in this model.
arc
ac20
4
What types of pipes are used in the building?
No Pipe segments or Pipe fittings were found in this model.
arc
ac20
4
Which heating systems are included in this building?
No explicit heating system components found.
arc
ac20
4
What is the thickness of the insulation of the external walls?
The external wall insulation is 42 mm thick.
arc
dental_clinic
1
What information is available about the insulation used in the external walls?
The insulation material is not explicitly defined in the BIM model. It is identified as an 'Insulated Panel' with a thickness of 42 mm.
arc
dental_clinic
4
How many X-RAY rooms are there in total?
There is 1 X-ray room (room 2A12).
arc
dental_clinic
2
What is the ceiling height in treatment room 2A12?
The ceiling height in treatment room 2A12 is 2.80 m.
arc
dental_clinic
1
Can you give me the list of all room types?
Based on the BIM model analysis, here is the complete list of all 29 room types found in the dental clinic: 1. Break Room (5 spaces) 2. Classroom (1 space) 3. Clean Room (2 spaces) 4. Conference Room (4 spaces) 5. Copy Room (1 space) 6. Corridor (40 spaces) 7. Dressing Room (2 spaces) 8. Electrical Room (5 spaces) 9. ...
arc
dental_clinic
2
What is the width of the main entrance door?
The width of the main entrance door is 1.8 m.
arc
dental_clinic
1
How many rooms are there in the clinic ?
There are 269 rooms in the clinic.
arc
dental_clinic
2
What is the total area of the sterilization rooms?
The total area of the sterilization rooms is 25.4 sqm. Included rooms: - 2C12 'DIPC CLEAN' - 2C10 'DIPC DECON'
arc
dental_clinic
2
End of preview. Expand in Data Studio

IFC-Bench

Dataset Version License QA Pairs

A benchmark dataset for evaluating BIM (Building Information Modeling) comprehension and reasoning capabilities in AI systems. Provides curated IFC models with question-answer pairs across 4 complexity categories for testing BIM-related AI implementations.

Dataset snapshot:

question ground_truth ifc_model project category
0 What modelling program and IFC standard were used to create this model? The model was created using... arc 4351 1
1 What are the estimated capacities for each waiting area in the building? The information is not directly available... arc dental_clinic 4
2 What are the slab types in the building, their quantities, and available thicknesses? The building contains the following slab types... arc fantasy_residential_building_1 2
3 What are all the residential units on level 8, with their approximate gross areas? Level 8 residential units... arc sixty5 3

Features

  • 22 BIM projects with 51 IFC models across architectural, structural, MEP, and specialty disciplines
  • 1,027 question-answer pairs covering diverse BIM information retrieval tasks
  • 4 question categories based on data retrieval complexity (direct retrieval, computational aggregation, geometric/spatial computation, incomplete information)
  • Rich contextual data: original IFC files, model cards, license documentation
  • Machine-readable format: CSV dataset with clear column structure
  • Versioned: V2 dataset with V1 preserved for backwards compatibility

Dataset Structure

ifc-bench/
β”œβ”€β”€ projects/
β”‚   β”œβ”€β”€ 4351/
β”‚   β”œβ”€β”€ ac20/
β”‚   β”œβ”€β”€ city_house_munich/
β”‚   β”œβ”€β”€ dental_clinic/
β”‚   β”œβ”€β”€ digital_hub/
β”‚   β”œβ”€β”€ duplex/
β”‚   β”œβ”€β”€ ettenheim_gis/
β”‚   β”œβ”€β”€ fantasy_hotel_1/
β”‚   β”œβ”€β”€ fantasy_hotel_2/
β”‚   β”œβ”€β”€ fantasy_office_building_1/
β”‚   β”œβ”€β”€ fantasy_office_building_2/
β”‚   β”œβ”€β”€ fantasy_office_building_3/
β”‚   β”œβ”€β”€ fantasy_residential_building_1/
β”‚   β”œβ”€β”€ fzk_house/
β”‚   β”œβ”€β”€ hitos/
β”‚   β”œβ”€β”€ molio/
β”‚   β”œβ”€β”€ samuel_macalister_sample_house/
β”‚   β”œβ”€β”€ schependomlaan/
β”‚   β”œβ”€β”€ sixty5/
β”‚   β”œβ”€β”€ smiley_west/
β”‚   β”œβ”€β”€ wbdg_office/
β”‚   └── west_riverside_hospital/
β”‚       β”œβ”€β”€ arc.ifc            # IFC model files
β”‚       β”œβ”€β”€ model_card.md      # Project metadata
β”‚       β”œβ”€β”€ license.txt        # Model license
β”‚       └── snapshot.png       # Visual snapshot
β”œβ”€β”€ questions/
β”‚   β”œβ”€β”€ ifc-bench-v2.csv       # V2 dataset (1,027 QA pairs)
β”‚   └── ifc-bench-v1.csv       # V1 dataset (preserved)
└── docs/
    └── CONTRIBUTING.md

Models Overview

Project Disciplines License Usage Source
4351 Architecture GNU GPL v3 unspecified BIMserver TestFiles
ac20 Architecture CC BY 4.0 office KIT IFC Examples
city_house_munich Architecture CC BY 4.0 living N/A
dental_clinic Architecture, Structural, MEP CC BY 4.0 healthcare buildingSMART
digital_hub Architecture, Heating, Plumbing, Ventilation MIT office RWTH E3D
duplex Architecture, MEP CC BY 4.0 living buildingSMART
ettenheim_gis GIS GNU GPL v3 mix BIMserver TestFiles
fantasy_hotel_1 Architecture MIT hospitality TUM BIM Fundamentals SS2025
fantasy_hotel_2 Architecture MIT hospitality TUM BIM Fundamentals SS2025
fantasy_office_building_1 Architecture MIT office TUM BIM Fundamentals SS2025
fantasy_office_building_2 Architecture MIT office TUM BIM Fundamentals SS2025
fantasy_office_building_3 Architecture MIT office TUM BIM Fundamentals SS2025
fantasy_residential_building_1 Architecture MIT living TUM BIM Fundamentals SS2025
fzk_house Architecture CC BY 4.0 living KIT IFC Examples
hitos Architecture GNU GPL v3 office BIMserver TestFiles
molio Architecture CC BY 4.0 office buildingSMART
samuel_macalister_sample_house Architecture, MEP GNU GPL v3 living BIMserver TestFiles
schependomlaan Architecture CC BY 4.0 living openBIM Archive
sixty5 Architecture, Electrical, Facade, Kitchen, Plumbing, Structural, Ventilation CC BY 4.0 living buildingSMART
smiley_west Architecture CC BY 4.0 living KIT IFC Examples
wbdg_office Architecture, MEP, Structural CC BY 4.0 office WBDG
west_riverside_hospital Architecture, Structural, Mechanical, Plumbing, Electrical, Fire Alarm, Sprinklers CC BY 3.0 healthcare OpenIFC Model Repository

4351

ac20

city_house_munich

dental_clinic

digital_hub

duplex

ettenheim_gis

fantasy_hotel_1

fantasy_hotel_2

fantasy_office_building_1

fantasy_office_building_2

fantasy_office_building_3

fantasy_residential_building_1

fzk_house

hitos

molio

samuel_macalister_sample_house

schependomlaan

sixty5

smiley_west

wbdg_office

Question Taxonomy

Questions are classified into 4 categories based on data retrieval complexity and computational requirements, adapted from the classification framework by Solihin et al. (2015) for automated BIM compliance checking.

Category Name Count Description
1 Direct Information Retrieval 152 Answerable through direct access to explicitly stored BIM element properties, without requiring computation.
2 Computational Aggregation 569 Require simple, unambiguous mathematical operations (counting, summation, averaging, filtering) on directly accessible data.
3 Geometric/Spatial Computation 112 Require complex computations involving geometric properties, spatial relationships, or derived measurements not directly stored.
4 Incomplete Information 194 The required information is not fully available in the BIM model; answering requires assumptions or acknowledging limitations.

For details on how the taxonomy is used in evaluation, see:

Hellin, S., Nousias, S., & Borrmann, A. (2026). Evaluating AI Systems for BIM Information Retrieval: A Multi-Dimensional Framework Beyond Binary Accuracy. GNI 2026.

Getting Started

Prerequisites

  • Python 3.8+
  • uv (recommended for virtual environment management)

Quick Start

git clone https://github.com/sylvainHellin/ifc-bench.git
cd ifc-bench

# Install dependencies (using uv)
uv pip install pandas ifcopenshell

Using the Dataset

import pandas as pd

# Load V2 dataset
df = pd.read_csv('questions/ifc-bench-v2.csv')

print(f"Total QA pairs: {len(df)}")
print(f"Projects: {df['project'].nunique()}")
print(f"Category distribution:\n{df['category'].value_counts().sort_index()}")

# Filter by category
spatial_questions = df[df['category'] == 3]
print(f"\nGeometric/Spatial questions: {len(spatial_questions)}")

# Filter by project
duplex_questions = df[df['project'] == 'duplex']
print(f"Duplex questions: {len(duplex_questions)}")

Dataset Columns

Column Description Example
question Natural language question about a BIM model "What is the total gross floor area of the building?"
ground_truth Reference answer "The total gross floor area is 354.67 sqm"
ifc_model Model filename (without .ifc extension) "arc"
project Project name (matches directory under projects/) "duplex"
category Question complexity category (1-4) 2

Dataset Integrity

Verify dataset integrity using SHA-256 checksums:

# V2 dataset
shasum -a 256 questions/ifc-bench-v2.csv
# Expected: 8f08f5d04834a79310eb7de81f2d6812e74d53a01363affdb815bf86dfc4dbf4

# V1 dataset (preserved for backwards compatibility)
shasum -a 256 questions/ifc-bench-v1.csv
# Expected: f67a48770d74b6e0ff0868c923c3e1d976110350b2c439564d7ceccc16a46f35

Contributing

We welcome contributions:

  • New IFC models (with permissive licensing)
  • Additional QA pairs for existing models
  • Documentation improvements
  • Error corrections in existing answers

Please see our Contribution Guidelines for details.

License

  • Dataset (question-answer pairs, documentation, model cards, and all original content): Licensed under CC BY 4.0.

  • IFC models: Each model retains its original license as specified in its project's license.txt. The majority of models are licensed under CC BY 4.0 or MIT. However, the following models are licensed under GNU GPLv3 and are subject to its copyleft terms:

    Users who redistribute or create derivative works that include these GPLv3 model files must comply with the GPLv3 license terms for those files. See each project's license.txt for details.

Citation

If using IFC-Bench in research, please cite the paper that introduces the v2 benchmark (currently a preprint, submitted to Automation in Construction; this entry will be updated once the paper is accepted):

@misc{hellinBIMInformationExtraction2026,
  title = {{{BIM Information Extraction Through LLM-based Adaptive Exploration}}},
  author = {Hellin, Sylvain and Jang, Suhyung and Fuchs, Stefan and Nousias, Stavros and Borrmann, Andr{\'e}},
  year = 2026,
  eprint = {2605.01698},
  archivePrefix = {arXiv},
  primaryClass = {cs},
  doi = {10.48550/arXiv.2605.01698},
  url = {https://arxiv.org/abs/2605.01698},
  note = {Preprint, submitted to Automation in Construction}
}

The v1 benchmark was introduced in:

@inproceedings{hellinNaturalLanguageInformation2025,
  title = {Natural {{Language Information Retrieval}} from {{BIM Models}}: {{An LLM-Based Agentic Workflow Approach}}},
  booktitle = {{{EC3}}},
  author = {Hellin, Sylvain and Nousias, Stavros and Borrmann, Andr{\'e}},
  year = 2025,
  doi = {http://www.doi.org/10.35490/EC3.2025.265},
  abstract = {While Building Information Models (BIM) effectively store building-related information, accessing it requires specialized software and expertise. Natural Language (NL) interfaces for BIM data retrieval can mitigate this challenge, but existing approaches are limited by rigid ontological frameworks or extensive pre-processing requirements. We present a Large Language Model-based agentic workflow that processes NL queries and automatically interacts with IFC-encoded BIM models without ontological or pre-processing constraints. In tests across architectural, structural, and MEP domains, our approach achieves 80\% overall accuracy. We provide open access to IFC-Bench-v1, our evaluation dataset containing various queries, answers, and reference BIM models.},
  copyright = {CC0 1.0 Universal Public Domain Dedication},
  langid = {english}
}

Acknowledgments

  • buildingSMART International for providing sample files
  • RWTH Aachen University E3D Institute for the Digital Hub models
  • KIT IAI for IFC example models
  • Tamira Wrabel, Sebastian Esser and Zijian Wang for preparing and curating the BIM Fundamentals SS2025 student models
  • TUM BIM Fundamentals SS2025 students for fantasy building models
  • Selahattin Doelger for the Sixty5 models
  • The openBIM community for quality assurance
  • Wawan Solihin (Singapore) for donating the West Riverside Hospital multi-discipline IFC models
  • Professor Robert Amor (University of Auckland) for hosting the models on the OpenIFC Model Repository

Maintainer: Sylvain Hellin | Contact: sylvain.hellin@tum.de | Issues: GitHub Issues

Downloads last month
1,151

Paper for sylvainHellin/ifc-bench